Rollup Monitors Showing an Incorrect State

I had a persistent problem on one of my OpsMgr managed agents, who had an incorrect state rollup.  In other words, the parent monitor showed a warning state, even though all child monitors we in a healthy state.

I tried the accepted procedure of putting the health service and health service watcher in maintenance mode, waiting for the agent to show NOT MONITORED, then stopping maintenance mode, but this didnt work.

I resolved the issue by restarting the OpsMgr health service on the agent WHILE it was in maintenance mode, and the issue resolved.